CHP Unit type |
Electrical Output (kW) |
Heat Output (kW) standard / increased 1 |
Electrical Efficiency |
Heat Efficiency (%) standard / increased 1 |
Total Efficiency (%) standard / increased 1 |
Emission NOx/CO (mg/Nm3) |
Micro 30 |
20 |
43.3 / 48.8 |
30.0 |
64.9 / 73.2 |
94.9 / 103.2 |
95 / 250 |
Micro 30 |
30 |
58.1 / 65.4 |
32.4 |
62.8 / 70.7 |
95.2 / 103.1 |
95 / 250 |
Micro 50 |
50 |
88.5 / 101.6 |
34.2 |
60.6 / 69.5 |
94.8 / 103.7 |
95 / 250 |
Cento 80 |
81 |
119 / 128 |
35.2 |
51.7 / 55.7 |
86.9 / 90.9 |
500 / 650 |
Cento 100 |
104 |
141 / 155 |
37.1 |
50.4 / 55.4 |
87.5 / 92.5 |
500 / 650 |
Cento 120 |
125 |
177 / 194 |
36.3 |
51.5 / 56.4 |
87.8 / 92.7 |
500 / 650 |
Cento 160 |
164 |
220 / 241 |
37.8 |
50.7 / 55.5 |
88.5 / 93.3 |
500 / 650 |
Cento 180 |
184 |
231 / 255 |
39.2 |
49.3 / 54.4 |
88.5 / 93.6 |
500 / 650 |
Cento 200 |
200 |
252 / 277 |
39.2 |
49.4 / 54.3 |
88.6 / 93.5 |
500 / 650 |
Flexi 260 |
260 |
370 / 392 |
38.0 |
54.0 / 57.2 |
92.0 / 95.2 |
95 / 250 |
Flexi 350 |
354 |
439 / 482 |
40.2 |
49.8 / 54.7 |
90.0 / 94.9 |
500 / 650 |
Flexi 430 |
430 |
610 / 668 |
37.0 |
52.5 / 57.4 |
89.5 / 94.4 |
250 / 650 |
Flexi 530 |
528 |
671 / 738 |
39.3 |
50.0 / 55.0 |
89.3 / 94.3 |
250 / 650 |
Quanto 600 |
600 |
690 / 802 |
42.0 |
48.4 / 56.2 |
90.4 / 98.2 |
250 / 650 |
Quanto 800 |
800 |
911 / 1,059 |
42.3 |
48.2 / 56.1 |
90.5 / 98.4 |
250 / 650 |
Quanto 1000 |
999 |
1,155 / 1,359 |
42.0 |
48.5 / 57.1 |
90.5 / 99.1 |
250 / 650 |
Quanto 1200 |
1,200 |
1,354 / 1,576 |
42.6 |
48.0 / 55.9 |
90.6 / 98.5 |
250 / 650 |
Quanto 1600 |
1,560 |
1,788 / 2,080 |
42.2 |
48.4 / 56.3 |
90.6 / 98.5 |
250 / 650 |
Quanto 1800 |
1,840 |
1,996 / 2,105 |
43.6 |
47.3 / 49.9 |
90.9 / 93.5 |
250 / 650 |
Quanto 2300 |
2,300 |
2,451 / 2,863 |
44.0 |
46.9 / 54.7 |
90.9 / 98.7 |
250 / 650 |
Quanto 3000 |
3,203 |
3,666 / 3,856 |
42.1 |
48.2 / 50.7 |
90.3 / 92.8 |
250 / 650 |
Quanto 4000 |
4,500 |
4,799 / 5,066 |
43.7 |
46.6 / 49.2 |
90.3 / 92.9 |
250 / 650 |
* with additional exhaust heat exchanger
** in program Start
¹ seasonal space heating energy efficiency A++ classified unit
We offer the version with NOx emissions below 100 mg/m3 for the selected units.
For detailed technical information see the CHP Unit Types Overview brochure.
You will find comprehensive information on cogeneration in the TEDOM Cogeneration brochure as well. Take a look at the TEDOM Micro brochure. The option of various combinations of more CHP units in one container is offered in the container version CHP units. Technical data on these CHP units and their designs are available on request. Aside from the steel container version we also offer the concrete container version.